Heat Trace HTSX - Dây gia nhiệt Thermon
Heat tracing

1. SELF-REGULATING HEAT TRACING 39W – Thermon USA

92 / 100 Điểm SEO

Self-Regulating Heat Tracing Cable General HTSX 12-2 OJ ( 39W/m)

SELF-REGULATING HEAT TRACING

General

-Area classification: Class I, Zones 1 and 2, AEx e II Specification -Supply voltage: 220VAC

-Parallel circuit heating cable

-Construction: Copper conductors 2.0mm 2 min./ (self-regulating conductive core)/ Fluoropolymer insulation/ Copper braid/ Fluoropolymer outer jacket.

-Maximum exposure temperature (continuous power on): 260°C

-Temperature classification: T2

-Nominal power output: 39W/m @10°C

1. SELF-REGULATING HEAT TRACING 39W - Thermon USA
1. SELF-REGULATING HEAT TRACING 39W – Thermon USA

Surface Sensing Electronic Thermostat ZT-C-100-P-XP

Enclosure rating……………………………………………….. IP66

Maximum pipe exposure temperature…………….. 250°C

Minimum installation temperature…………………….-60°C

Operating ambient temperature -60°C ≤ Ta ≤ +55°C……………….16

Amps Max, T6 85°C -60°C ≤ Ta ≤ +50°C……………..25

Amps Max, T5 100°C

Voltage rating………….. 230 Vac nominal up to 253 Vac1

Switch rating ………………………25 A (Ohmic, NC contact)

Switch type……………………………………………… Controller

Electrical connection2………………………..Terminal block3

Adjustable control range4

ZT-C-100 ……………………………………….. 0°C to 100°C

Maximum control differential/accuracy

ZT-C-100 …………………………………..7% / -1 K to +7 K

Maximum bulb exposure temperature

ZT-C-100 …………………………………………………. 230°C

Bulb dimensions/material/capillary length

ZT-C-100 ………………… 6 x 76 mm/stainless steel/1 m

Thermostat ZT-P-XP.

Surface Sensing Electronic Thermostat ZT-C-100-P-XP
Surface Sensing Electronic Thermostat ZT-C-100-P-XP

Low-Profile End Seal Kit ZE-XP End Terminator Kit

Low-Profile End Seal Kit

– Area classification: Class I, Zone 2, Gas group IIA, Temperature Class T3

– Use for heating cable in item 1.

– Explosion protection: Ex ‘e’

– Degree of protection: IP56 as minimum

– Maximum pipe temperature: 110°C

– Operating voltage: 220VAC ± 5%

– Materials of construction Enclosure, end plate, and shim: engineering polymers, black o Sealing grommet and core sealer: Silicone rubber o Screws, compression spring, reinforcement plate: stainless steel

Low-Profile End Seal Kit ZE-XP End Terminator Kit
Low-Profile End Seal Kit ZE-XP End Terminator Kit

Fixing Tape

FT-1L Glass cloth tape for attaching heating cable to pipe (not for stainlesssteel pipes),

– Length 20m/roll

– Width: 12mm

Fixing Tape
Fixing Tape

Pipe Strap

B-10 banding Pipe Strap stainless steel 2 in to 10 in

Pipe Strap
Pipe Strap

Warning Label

CL-E-US-END Warning Label

– Electric Traced Label for traced pipes.

– Language: English

Tank Adapter

XP-1-150 x 150 Tank adapter is used for mounting junction box, end seal kit on the tank surface.

Tank Adapter XP-1-150 x 150
Tank Adapter XP-1-150 x 150

Heat Trace HTSX – Dây gia nhiệt, cáp gia nhiệt, cáp duy trì nhiệt độ Thermon 2023

Giải pháp duy trì nhiệt độ cho lưu chất sáp định hình – Heat trace KSX/Thermon USA

Heat Trace – Dây gia nhiệt chống đông chất lỏng và kiểm soát nhiệt độ của đường ống

 

Liên hệ:

Công ty TNHH Wili Việt Nam

Email: Hung.tran@wili.com.vn

SDT: 0903 710 753

Liên quan...

Chủ đề phổ biến