| Temperature Sensor,TC, Type K, Dual element, No connection head, Flying leads, sensor length 660 mm | 0185N005K1N0000N0660I1 | EMERSON/ROSEMOUNT |
| Temperature Transmitter, Head mount, 4-20 mA with digital signal base on hart protocol, ATEX Intrinsically safe, 60 Hz Line Voltage Filter | 644HAI1F6Q4 | EMERSON |
| Conductivity Standard 200 µS/cm, 1-QUART | 5010781899 | EMERSON |
| Buffer solution pH4.01, 16oz | 9210012 | EMERSON/ROSEMOUNT |
| Buffer Solution, 6.86pH, 16 oz | 9210013 | EMERSON |
| Buffer Solution, 9.18 pH, 16 oz | 9210014 | EMERSON |
| pH Sensor Type Insertion /Submersion Sensor with integral cable, General Purpose Low resistivity GPLR pH Glass, No preamplifier, transmitter type 5081 | 389-01-10-55 | EMERSON |
| pH Sensor Type Insertion /Submersion Sensor with integral cable, General Purpose Low resistivity GPLR pH Glass, No preamplifier, transmitter type 5081 | 396P-01-10-55 | EMERSON |
| Dissolved Oxygen Sensor for transmitter type 5081A-HT, 0-10ppm. | 499ADO-54 | EMERSON |
| Electronic board for voltex flow transmitter-Model 8800 | 08800-5107-4501 | EMERSON |
| Condensor Dump Temperature Sensor, PT100, single element 3 wire, Φ 6, Length 100 mm, 1/4 NPT, cable 5m | | |
| Temperature Sensor, RTD, range -196-600oC, no conection head, Flying leads, duel element 3-wire, sensor length 260 mm, Eex ia-ATEX/IBExU. | 0065N04N0000N0260I1 | ROSEMOUNT |
| Temperature Sensor, RTD, range -50-450oC, no conection head, Flying leads, duel element 3-wire, sensor length 365 mm | 0065N02N0000N0365I1 | Emerson/ Rosemount |
| Free chlorine sensor, range 0-10ppm, Type Insertion /Submersion Sensor, for transmitter type 5081A-HT | 499ACL-01-54 | EMERSON |
| Temperature Transmitter, Head mount, 4-20 mA with digital signal base on hart protocol, ATEX Intrinsically safe, 60 Hz Line Voltage Filter | 644HAI1F6Q4 | EMERSON |
| Electronic board for voltex flow transmitter-Model 8800 | 08800-5107-4501 | EMERSON |
| Temperature Sensor,TC, Type K, Dual element, No connection head, Flying leads, sensor length 1365 mm, EEx ia-ATEX/IBExU, assemble sensor to Specific temperature transmitter | 0185N005K1N0000N1365I1XA | EMERSON/ROSEMOUNT |
| Pressure transmitter, range: (-1.01÷275)bar, (4÷20)mA. Accuracy: 0.065%FS. LCD display for Aluminum Housing. C/W diaphragm seal | 3051TG4A2B21AB4I1M5P1Q4Q8S1, 1199WDC56WFEY7A6280 | EMERSON/ROSEMOUNT |
Pressure transmitter. Range: (-1.01÷55.2)bar, (4÷20)mA. Accuracy: 0.065%FS. LCD display for Aluminum Housing. C/W diaphragm seal. Pressure transmitter. Range: (-1.01÷55.2)bar, (4÷20)mA. Accuracy: 0.065%FS. LCD display:5-Digit, 2-Line and 90-degree rotation capability. Diaphragm seal:Seal Style Flanged Extended . Process Connection Type ANSI Raised Face Standard (125-250 Ra) . Process Conn. Size (FE Ext. Dia.) : 3″ (Ext Dia. Special) . Process Connection Rating: 600# . Instrument Connection. 13mm Welded (BA20000) . Process Materials: (Wetted Gasket Area) 316LSS . Non-Wetted Materials (Flange): 316LSS . Diaphragm Materials (Wetted): 316LSS . Extension Length : 40 mm, Option#1 : Extended Seal Diameter 2.7165″ (69mm) /Option#2 : Flanged Extended with non-rotating flange (one-piece).Flange diameter:210 mm, Flange thickness: 32 mm, Number of bolts: 8, Bolt hole diameter: 22 mm, Raised face diameter: 127 mm, Extended Seal Diameter: 69 mm. capillary length: 3m | 3051TG3A2B21AB4I1M5P1Q4Q8S1. C/W: 1199WDC56WFE1HA6 | EMERSON |
| Differential Pressure transmitter. Range: (–623 + 623)mbar, (4÷20)mA. Accuracy: 0.065%FS. Conn: ½”–14 NPT Female. Traditional Flange, 316 SST, SST Drain/Vent LCD display for Aluminum Housing Assembly to Rosemount 306 Integral Manifold | 3051CD2A02A1AM5I1H2L4P1Q4Q8 | EMERSON/ROSEMOUNT |
| Temperature Sensor,TC, Type K, Dual element, No connection head, Flying leads, sensor length 1365 mm, EEx ia-ATEX/IBExU, assemble sensor to Specific temperature transmitter | 0185N005K1N0000N1365I1XA | EMERSON/ROSEMOUNT |
| Temperature Transmitter, 4-20 mA, Dual Sensor input, FM IS, LCD Display, Certificate 3 poin Calibration | 3144PD1A2K5M5Q4 | EMERSON |
| Pressure transmitter, range: (-1.01÷275)bar, (4÷20)mA. Accuracy: 0.065%FS. LCD display for Aluminum Housing. C/W diaphragm seal | 3051TG4A2B21AB4I1M5P1Q4Q8S1, 1199WDC56WFEY7A6280 | EMERSON/ROSEMOUNT |
| Electronics as’y, includes alarm jumper and captive screws for Displacer level transmitter-DLC 3010 | 18B5529X022 | FISHER |